Stormwater Drainage Tools

SCS Curve Number Method — Rainfall–Runoff Summary & Calculation Solver

Interactive summary and solver for the SCS (NRCS) Curve Number runoff method — compute retention S, initial storage Iₐ and runoff depth Q from rainfall, soil group and land cover.

§3.4 — SCS Curve Number Method · Design Sheet
§3.4 · SCS Curve Number Method
Q = — mm
DRAINAGE DESIGN MANUAL · RAINFALL–RUNOFF

Soil Conservation Service (SCS) Method

Developed by the U.S. Department of Agriculture, Soil Conservation Service — now the Natural Resources Conservation Service (NRCS) — to predict direct runoff volumes for given rainfall events, using a runoff equation and a unit hydrograph to route runoff to the catchment outlet.

USDA · NRCSCatchment > 80 haAMC II · Iₐ = 0.2 SSCS Type II curve
SECTION 01

Overview & Hydrologic Soil Groups

TABLE 3-10

Runoff is calculated from a series of runoff curves describing an initial storage followed by runoff increasing with rainfall. Initial infiltration and subsequent runoff are parameterised by a curve number, selected by ascertaining the dominant soil type and its hydrologic soil group, then the most appropriate land cover. If no information on soils exists, assume Group B.

STEP 1Soil group

Ascertain dominant soil texture → hydrologic group (Table 3-10); default Group B.

STEP 2Land cover

Select the most appropriate cover complex → CN (Table 3-11).

STEP 3Runoff depth

Compute S and Iₐ; confirm P > Iₐ; solve the runoff equation for Q.

STEP 4Routing

Route to the outlet with the unit hydrograph (Type II cumulative).

SECTION 02

Governing Equations

§3.4.1 · CURVE NUMBER

INITIAL STORAGE (MM)

Ia = 0.2 × (1000CN − 10) × 25.4
→

RUNOFF DEPTH (MM)

Q = (P − 0.2S)2(P + 0.8S)
→

MAX. RETENTION (MM)

S = 25400CN − 254
Prainfall depth (mm)
Qdirect runoff depth (mm)
Spotential maximum soil moisture retention (mm)
CNcurve number (dimensionless)
NOTE — Iₐ = 0.2·S · THE RUNOFF EQUATION APPLIES ONCE RAINFALL EXCEEDS THE INITIAL STORAGE; OTHERWISE Q = 0
SECTION 03

Calculation Worksheet

LIVE SOLVER

Complete the design inputs — the results panel, computation log and Figure 3-9 update as you type.

DESIGN INPUTSSCS-CN
—
—mm
Potential maximum retention, S
— mm
Initial storage, Iₐ
— mm
Runoff coefficient, Q/P
—

COMPUTATION LOG

    Figure 3-9 — Runoff curves for different SCS curve numbers, recreated interactively. The active CN curve is drawn in green and the current design point is marked; the shaded band indicates the no-runoff zone (P ≤ Iₐ).
    SECTION 04

    Runoff Curve Numbers

    TABLE 3-11 · AMC II, I = 0.2S · SCS 1983

    Table taken from the DEPARTMENT Road Drainage Manual. Click any row to load its curve number into the worksheet for the active soil group.

    LAND USE DESCRIPTIONABCD
    SECTION 05

    Urban Composite Method

    ALTERNATIVE APPROACH

    If modelling an urban catchment where the appropriate average percent impervious area is not listed in Table 3-11, or the pervious areas are not best described as “lawns in good condition”: (i) estimate the CN for the pervious area; (ii) estimate the CN for the impervious area; (iii) estimate the runoff from each separately, then summate for downstream runoff.

    COMPOSITE INPUTSi – iii
    SUMMATED · STEP iii
    Runoff — pervious area, Qp
    — mm
    Runoff — impervious area, Qi
    — mm
    Total downstream runoff, Q
    — mm

    COMPUTATION

      SECTION 06

      Table 3-11 Footnotes

      NOTES 1–6
      1. For land uses with pervious areas, curve numbers are computed assuming that 100% of runoff from previous areas is directly connected to the drainage system. Pervious areas (lawn) are considered to be equivalent to lawns in good condition and the impervious areas have a CN of 98.
      2. Use for the design of temporary measures during grading and construction.
      3. For contoured tillage poor hydrologic conditions, 5 to 20 percent of the surface is covered with residue. For contoured tillage good hydrologic condition, more than 20 percent of the surface is covered with residue.
      4. Close-drilled or broadcast.
      5. Poor hydrologic condition has less than 25 percent ground cover density. Fair hydrologic condition has between 25 and 50 percent ground cover density. Good hydrologic condition has more than 50 percent ground cover density.
      6. Poor hydrologic condition has less than 30 percent ground cover density. Fair hydrologic condition has between 30 and 70 percent ground cover density. Good hydrologic condition has more than 70 percent ground cover density.
      §3.4 SCS Method — Design Sheet. Data: SCS (1983), via DEPARTMENT Road Drainage Manual. Set in Source Serif 4, Public Sans & IBM Plex Mono · Verify inputs before design use.